Browse Source

hw/timer/aspeed: Fix interrupt status does not be cleared for AST2600

According to the datasheet of AST2600 description, interrupt status set by HW
and clear to "0" by software writing "1" on the specific bit.

Therefore, if firmware set the specific bit "1" in the interrupt status
register(0x34), the specific bit of "s->irq_sts" should be cleared 0.

Signed-off-by: Jamin Lin <jamin_lin@aspeedtech.com>
Fixes: fadefada4d07 ("aspeed/timer: Add support for IRQ status register on the AST2600")
Reviewed-by: Andrew Jeffery <andrew@codeconstruct.com.au>
Reviewed-by: Cédric Le Goater <clg@redhat.com>
Jamin Lin 9 tháng trước cách đây
mục cha
commit
d3d6def468
1 tập tin đã thay đổi với 1 bổ sung1 xóa
  1. 1 1
      hw/timer/aspeed_timer.c

+ 1 - 1
hw/timer/aspeed_timer.c

@@ -580,7 +580,7 @@ static void aspeed_2600_timer_write(AspeedTimerCtrlState *s, hwaddr offset,
 
     switch (offset) {
     case 0x34:
-        s->irq_sts &= tv;
+        s->irq_sts &= ~tv;
         break;
     case 0x3C:
         aspeed_timer_set_ctrl(s, s->ctrl & ~tv);